From NEI’s Japan Earthquake launch page:

UPDATE AS OF 11:20 A.M. EDT, FRIDAY, MARCH 18:
Reactors 1, 2 and 3 at the Fukushima Daiichi nuclear power plant are in stable condition, with workers continuing to provide seawater cooling into the reactors. Containment integrity is believed to be intact on reactors 1, 2 and 3, and containment building pressures are elevated but are within design limits.

Site radiation doses have been decreasing since March 16. Radiation dose rates are fluctuating based on some of the relief operations, such as adding cooling water to the used fuel pools. Recent readings at the plant boundary are about 2 millirem per hour. Radiation dose rates at reactor 3 range between 2,500 and 5,000 millirem per hour.
The Japanese Self-Defense Force restarted cooling water spray into the Unit 3 reactor building and spent fuel pool at around 1 a.m. EDT on March 18. Plans are to spray 50 tons of water on the reactor 3 reactor building/spent fuel pool using seven fire-fighting trucks.
A diesel generator is supplying power to reactors 5 and 6. TEPCO is installing high voltage cables from a nearby transmission line to reactors 1 and 2. Once electricity supply is re-established, priority will be given to restoring power to reactor heat removal systems and cooling water pumps. Workers are seeking to install electrical cables to reactors 3 and 4 components in about two days.

Fukushima Daini

All four reactors at Fukushima Daini remain shut down with normal cooling being maintained using residual heat removal systems.
Daiichi Accident Rated 5 on International Event Scale
New International Nuclear and Radiological Event Scale (INES) ratings have been issued for the accident at the Fukushima Daiichi and Daini nuclear power plants, the International Atomic Energy Agency said.
Reactor core damage at the Daiichi reactors 2 and 3 caused by a loss of cooling function has resulted in a rating of 5 on the seven-point scale.

The loss of cooling and water supply functions in the spent fuel pool of reactor 4 was rated a 3, or "serious" incident. The loss of cooling functions in the reactors 1, 2 and 4 of the Fukushima Daini nuclear power plant has led to a rating of 3.

The rating for the Chernobyl accident was 7, or a "major accident" on the INES scale. The Three Mile Island accident was 5, or an "accident with wider consequences." For more information on INES, see the IAEA's website and this IAEA leaflet.

Comments

Popular posts from this blog

Activists' Claims Distort Facts about Advanced Reactor Design

Below is from our rapid response team . Yesterday, regional anti-nuclear organizations asked federal nuclear energy regulators to launch an investigation into what it claims are “newly identified flaws” in Westinghouse’s advanced reactor design, the AP1000. During a teleconference releasing a report on the subject, participants urged the Nuclear Regulatory Commission to suspend license reviews of proposed AP1000 reactors. In its news release, even the groups making these allegations provide conflicting information on its findings. In one instance, the groups cite “dozens of corrosion holes” at reactor vessels and in another says that eight holes have been documented. In all cases, there is another containment mechanism that would provide a barrier to radiation release. Below, we examine why these claims are unwarranted and why the AP1000 design certification process should continue as designated by the NRC. Myth: In the AP1000 reactor design, the gap between the shield bu...

What Happens During a Refueling Outage?

You may have noticed over the past few weeks that a number of nuclear plants are shut down for refueling outages or are resuming operations after just returning from one. This type of routine outage usually occurs in the spring or fall when electricity demand is low so that nuclear reactors can replace about one-third of the spent fuel rods with new fuel and conduct other routine maintenance and repairs at the plant. To get a better sense of how refueling works at a nuclear energy facility, I spoke with Marcus Nichol, NEI’s senior project manager for used fuel storage and transportation, and asked him to explain the basics. Why does a nuclear plant need to replace one-third of its fuel? Nichol: The main purpose of a refueling outage is to replace older fuel that is depleted—meaning it can no longer efficiently produce energy from nuclear fission reactions—with new fuel. This “used fuel” has typically been used in the reactor for four-and-a-half to six years before it is pe...

Nuclear Utility Moves Up in Credit Ratings, Bank is "Comfortable with Nuclear Strategy"

Some positive signs that nuclear utilities can continue to receive positive ratings even while they finance new nuclear plants for the first time in decades: Wells Fargo upgrades SCANA to Outperform from Market Perform Wells analyst says, "YTD, SCG shares have underperformed the Regulated Electrics (total return +2% vs. +9%). Shares trade at 11.3X our 10E EPS, a modest discount to the peer group median of 11.8X. We view the valuation as attractive given a comparatively constructive regulatory environment and potential for above-average long-term EPS growth prospects ... Comfortable with Nuclear Strategy. SCG plans to participate in the development of two regulated nuclear units at a cost of $6.3B, raising legitimate concerns regarding financing and construction. We have carefully considered the risks and are comfortable with SCG’s strategy based on a highly constructive political & regulatory environment, manageable financing needs stretched out over 10 years, strong partners...